The high performance liquid chromatography Diaries
The high performance liquid chromatography Diaries
Blog Article
크로마토그래피 원리의 큰 틀도 마찬가지로 두 상에 대한 분배 차이를 이용하여 분석물을 분리, 정제할 수 있습니다. 다만 크로마토그래피에서 두 개의 상은 하나는 고정하고 다른 하나는 일정 방향으로 이동시켜 사용합니다.
. HPLC separation of a combination of flavonoids with UV/Vis detection at 360 nm and, in the inset, at 260 nm. The selection of wavelength affects Just about every analyte’s sign.
a values, the pH on the cell stage has a distinct impact on Each individual solute’s retention time, allowing for us to locate the ideal pH for effecting a whole separation with the four solutes.
Non-polar molecules are slowed down on their way throughout the column. They variety varying levels of attraction With all the hydrocarbon groups principally by means of van der Waals dispersion forces and hydrophobic interactions.
). Should the detector is often a diode array spectrometer, then we also can Show the result as a three-dimensional chromatogram that shows absorbance to be a operate of wavelength and elution time.
. Inside the load situation a sample loop—which is on the market in a number of sizes starting from 0.5 μL to 5 mL—is isolated in the cellular period and open up to your ambiance. The sample loop is stuffed utilizing a syringe which has a capacity numerous moments that of the sample loop, with extra sample exiting click here throughout the squander line.
Gas samples are gathered by bubbling them via a lure that contains an appropriate solvent. Organic isocyanates in industrial atmospheres are gathered by bubbling the air via an answer of one-(two-methoxyphenyl)piperazine in toluene. The reaction concerning the isocyanates and 1-(2-methoxyphenyl)piperazine both equally stabilizes them from degradation prior to the HPLC Examination and converts them to the chemical variety that may be monitored by UV absorption.
前述した従来の順相タイプに対して、逆相クロマトグラフィーにおいては固定相に低極性のもの(例えばシリカゲルにアルキル基を共有結合させたもの)を、移動相に高極性のもの(例えば水や塩類の水溶液、アルコール、アセトニトリルなどの有機溶媒)を用いる。また珍しいケースではあるが、分離のための移動相pHをシリカゲルの使用範囲から外れたところに設定する必要がある場合、あるいはシリカゲル表面に残っている未反応シラノール基が分離に悪影響を及ぼし、かつそれが移動相の変更によっても解決できない場合には、固定相として樹脂を用いることがある。分析物はより極性の低いほどより強く固定相と相互作用して溶出が遅くなる。また極性の低い物質の割合が多い移動相ほど溶出が早くなる。
The buy of elution of compounds in the column is ruled by the intensity of connection with the stationary section. The eluent Along with the divided chemical compounds flows previous the detector.
원하는 분석 결과를 얻기 위해서는 컬럼도 충분히 고려하고 선택하는 것이 좋습니다.
The stationary period is usually a solid assistance packed within a column, whereas the cell phase is frequently a liquid or a mix of liquids.
Because it works by using a loop injection, the precision of the HPLC strategy usually is a lot better than a GC method. HPLC is just not limited to unstable analytes, which implies we will assess a broader range of compounds. Capillary GC columns, Alternatively, have much more theoretical plates, and might individual far more advanced more info mixtures.
Soon after loading the sample, the injector is turned towards the inject placement, which redirects the cell stage in the sample loop and onto the column.
The injector introduces a precise quantity on the sample solution to the cellular phase stream. Numerous injection approaches exist, with loop injection currently being a typical strategy.